<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>laser</ParameterFamily>
<LongName>
laser_warmup_time
</LongName>
<Name>
tinit
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Green</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Ignored when "laser ver" set to 0 (no laser). If laser ver = 1 or 2 (Adlas laser
or adlas laser integration mode), the default value of tinit is 10.  It may be set
as high as 20.
</text></DescriptionText>
<DescriptionText><text>
If laser ver = 10 (Coherent laser), set tinit to 2. There is no feedback from the
coherent laser to tell the firmware when the coherent laser is ready. Setting a
2 minute timeout gives the laser time to stabilize before the workstation is permitted
to launch jobs.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>10</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 254 [minutes]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/laser_cfg_ver.xml</LinkAddress><LinkTitle>NVS: laser ver</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/laser_cfg_tcon.xml</LinkAddress><LinkTitle>NVS: laser tcon</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:10 2008 PST
</Updated>
<Links>
</Links>
</Parameter>